Short answer: On 6 of the 8 heat pumps and mini-splits we checked for a cooling complaint between June and November 2026, the refrigerant side was the problem: a low charge, a leak or an empty system. On central ACs, 10 of 19 needed a new capacitor, a contactor or both. Check the thermostat, breakers and filter first, then wait 15 minutes before you book.
Your heat pump is set to cool and it’s running, but the air from the vents is warm or just room temperature. Or the outdoor unit sits silent while the indoor fan blows. Or it heated fine all winter and now won’t cool at all.
Those feel like one problem. They aren’t, and the fix for one does nothing for the others. Below is what our own cooling calls turned up, how to tell the causes apart, and what you can safely check yourself.
What we found on our 2026 cooling calls
Our CRM has 28 cooling systems between June 1 and November 13, 2026 where the complaint was a heat pump, mini-split, wall unit or central AC that wasn’t cooling, wasn’t working or wouldn’t turn on, and our write-up recorded what we found. Eight were heat pumps or ductless mini-splits, one was a through-the-wall unit and 19 were central air conditioners. We kept the ACs in because a heat pump in cooling mode does the same job as a central AC, and Carrier covers both in one service manual.
| What we found | Systems | What was reported | What it took |
|---|---|---|---|
| Refrigerant side, heat pumps and mini-splits | 6 | A mini-split wasn’t cooling or starting; a multi-zone mini-split cooled for 2 to 3 hours, then the indoor light blinked and cooling stopped; a heat pump wasn’t cooling; a multi-zone system gave no cooling and no heat; a system less than a year old wasn’t cooling and was noisy; a new mini-split started out cold, then wasn’t very cold | Low charge on 2, one with a suspected electronic expansion valve, each with a written estimate or recommendation. Leaks at flare connections on 3: on one, found on a follow-up visit, the paid repair covered reflaring the connections, a nitrogen purge, a triple vacuum and new refrigerant; at one address with two mini-splits, the flare connections had leaked since the original installation, and both systems were reinstalled with the connections reflared, the lines flushed, a triple vacuum and a fresh charge; on one, a paid repair invoice for the flare leak. An empty system on 1, refilled; cooling and heating came back, and fixing the leak means reflaring every connection |
| Heat pump fuse, fan motor and boards | 1 | One of two Daikin heat pumps showed only a blue light when switched on | A blown fuse, then a new outdoor fan motor. The main and filter boards were then found faulty, and a board was replaced |
| Capacitor or contactor | 8 | Not cooling, not working, the outdoor unit staying off, or the AC’s fan not running; on 4 the system ran but the air wasn’t cold | A new capacitor on 4, one with a control-board fuse. A new capacitor and contactor on 4: two with rewiring, and one with a dirty condenser coil cleaned and the filter replaced |
| Capacitor and contactor, plus refrigerant | 1 | The house stayed at 77 to 78 degrees with the AC on | A new capacitor and contactor, and refrigerant added |
| Refrigerant, central AC | 1 | The AC cooled slowly | The system was recharged with R-410A |
| Condenser fan motor | 2 | Warm air on one; the outdoor fan not running on the other | On one the fan motor had failed and needed replacing (a second system at that house needed replacement). On the other, a new fan motor and capacitor |
| Control wiring | 3 | The AC wasn’t working, wouldn’t turn on, or the outdoor unit wouldn’t run | On 1, no 24 volts reached the outdoor unit and the control cable under the floor needed replacing. On 1, wiring connections at the furnace were repaired and a fuse replaced. On 1, the thermostat and low-voltage control wiring were corrected and the condenser coils cleaned |
| Compressor | 1 | The AC wouldn’t turn on at all | The compressor had an internal short, and the furnace ground wire wasn’t connected |
| Condenser fan blocked | 1 | A wall unit wasn’t getting cold enough | Debris had stopped the condenser fan from turning; it was cleared and the area cleaned |
| Airflow | 2 | No cooling after hours on maximum with weak airflow at the vents; no air at all from the living room vents | The air filter needed replacing and holes in the air handler cabinet needed sealing. A duct section appeared to have come apart above the ceiling, with no access short of opening the ceiling |
| Clogged drain, then a control board | 1 | The AC stopped working | The drain line was unclogged and the tripped flood sensor reset. A recall visit followed, and later the furnace’s main control board was replaced |
| No fault found | 1 | A mini-split stopped working | It ran again after a restart and no part was replaced. The technician noted it seemed to cool less than the unit next to it and might need refrigerant |
Where those 28 were:
| City | Systems | What we found |
|---|---|---|
| Fremont | 7 | Capacitor and contactor 3, control wiring 2, airflow 1, flare leak 1 |
| Hayward | 3 | Capacitor and contactor 1, capacitor and contactor plus refrigerant 1, condenser fan motor 1 |
| San Ramon | 3 | Capacitor 2, drain and control board 1 |
| Dublin | 3 | Condenser fan motor and capacitor 1, refrigerant 1, airflow 1 |
| Saratoga | 1 | Low refrigerant, suspected expansion valve |
| Berkeley | 1 | Leak at a flare connection |
| Oakland | 1 | Flare connections leaking since installation |
| Concord | 1 | Fuse, outdoor fan motor and control board |
| Los Gatos | 1 | Low refrigerant, leak |
| Palo Alto | 1 | Empty system |
| Pleasanton | 1 | Capacitor |
| Union City | 1 | Capacitor and control-board fuse |
| Redwood City | 1 | Control wiring |
| Portola Valley | 1 | Compressor |
| Walnut Creek | 1 | Condenser fan blocked by debris |
| Danville | 1 | No fault found after a restart |
Method: jobs created June 1 to November 13, 2026, not canceled unless paid, with a written finding. Installs, maintenance visits, calls whose complaint wasn’t about cooling and jobs with no recorded complaint (for example a booking that says only “AC repair”) were left out. So were calls with no recorded cause: 8 more cooling calls, 6 of them other AC systems and 2 mini-splits. Follow-up visits to the same address were counted with the first. The CRM brand field is empty on most HVAC jobs, so we searched the job descriptions, notes and invoices. Eight heat pumps and mini-splits is a small sample, so read the refrigerant number as what we saw, not a rule.
How to tell the causes apart
The indoor fan runs but the outdoor unit doesn’t. Then nothing is moving heat out of the house, and you get room-temperature air. On our calls the outdoor-unit parts that failed were capacitors, contactors, condenser fan motors, one compressor and, on one heat pump, control boards, on 13 of the 28 systems. Three times the trouble was the control wiring, so the outdoor unit never got its 24-volt signal or the thermostat couldn’t send it. Carrier’s troubleshooting steps for an outdoor unit that won’t run go in the order a technician works: the 24-volt call from the thermostat, the pressure switches, the contactor, then the wiring, capacitor and compressor. Each of those needs a meter.
Both units run but the air isn’t cold enough. Now it’s about heat transfer. That’s where all 6 of our heat pump and mini-split refrigerant findings sat, along with the slow-cooling central AC we recharged. On 3 of those mini-splits the leak was at the flare connections, including a new one and a system less than a year old. Goodman’s homeowner section says a dirty indoor coil or restricted airflow can cause poor operation, and that dirt, leaves or debris on the outdoor coil restrict airflow too. It also explains that even a small hole in the coil tubing can eventually lose a large amount of refrigerant. On the Berkeley multi-zone mini-split the outdoor coil was heavily dirty as well, and on the Los Gatos heat pump the filter was too.
It cools for a while, then quits. Our Berkeley Daikin cooled for 2 to 3 hours, then the indoor unit’s green light started blinking and the cooling dropped off. The outdoor board’s diagnostic lights pointed to a refrigerant shortage, and a follow-up visit found the leak at a flare connection. A pattern like that is worth writing down for the technician, with how long it ran first.
It heats but won’t cool. That points at the cooling side of the circuit. A heat pump uses one refrigerant circuit for both seasons, and a reversing valve sends the refrigerant one way for heating and the other way for cooling. Carrier’s service manual for its 24 and 25 series splits says that on a call for cooling the thermostat connects R to O, and that circuit energizes the reversing valve into the cooling position. Goodman’s GSZ service manual says the same: the valve is energized through the thermostat’s O terminal. So a thermostat that isn’t set up for the heat pump, a fault on the O wire or a stuck valve can each leave you with heat only. Goodman’s manual notes a valve can stick in heating, in cooling or partway between. Our heat pump thermostat wiring guide covers the O terminal. We didn’t record a stuck valve on this year’s calls, though. The mini-split we checked in Saratoga heated well on our test but cooled poorly, and it was low on refrigerant, with its electronic expansion valve suspected.
The system stopped completely. Check whether a condensate safety switch tripped. On one San Ramon call the drain line was clogged and the flood sensor had shut the AC off. That house later needed a furnace control board too, so a tripped switch isn’t always the whole story.
What you can check first
These are the steps in the “Before Calling Your Servicer” list in Goodman’s condensing unit and heat pump installation and service reference. They’re safe and quick.
- Check the thermostat. Goodman says to confirm it’s properly set. For cooling, that means set to cool, with the set temperature below the room temperature.
- Wait 15 minutes. Goodman notes that some devices in the outdoor unit or in programmable thermostats hold the compressor off for a while and then reset on their own. Some power companies also install devices that shut off air conditioners for several minutes on hot days.
- Check the breakers and fuses. Goodman says to reset tripped breakers or replace failed fuses as necessary. If one opens again within thirty days, call a qualified servicer. Resetting it again and again without fixing the cause risks severe equipment damage.
- Check the disconnect switch near the indoor furnace or blower. Make sure it’s in the on position.
- Look at the outdoor unit. Make sure it isn’t covered on the sides or top, and remove anything that can be safely removed. If the unit is covered with dirt or debris, Goodman says to call a qualified servicer to clean it.
- Clear the vents. Make sure supply and return grilles aren’t blocked by rugs, curtains or furniture.
- Check the filter. If it’s dirty, clean or replace it. Goodman says to check filters at least once a month and never run the system without one.
- Listen. Goodman lists unusual noise from the outdoor unit as its own reason to call a servicer.
That’s where owner checks stop. Don’t open the electrical panel on the outdoor unit, and don’t touch the refrigerant lines. Carrier’s own valve test instructions tell technicians not to touch the lines and to read their temperatures with remote probes.
What we check
If the outdoor unit isn’t running, we start with the thermostat signal at the unit, then the contactor, capacitor and pressure switches. If it is running, we put gauges on the system and read the operating pressures, then check airflow, the coils and, on a heat pump, the reversing valve. On the Palo Alto Fujitsu, a system with 4 indoor units, the low side read 16 psi. The system was empty, and the owner had no cooling even after another company refilled it. We recovered the old refrigerant, pulled a vacuum, pressure-tested and refilled it with new R-410A. Cooling and heating came back with a 17 to 20 degree temperature drop across the indoor units. A refill isn’t a repair, though. Fixing the leak there means reflaring every connection.
What it costs
The $99 diagnostic is credited toward an approved repair, and a written estimate comes after diagnosis and before any repair work. Typical minor HVAC repairs, such as a capacitor or contactor, run $250 to $650, parts and labor. A refrigerant leak, a valve or a compressor is a bigger job, and you’ll see that price in writing before you decide. More in our capacitor replacement cost guide.
When to book
Book if the air is still warm after the checks above and a 15-minute wait. Book right away if the breaker trips again, the outdoor unit hums but won’t start, you hear grinding or loud buzzing, or you see ice on the indoor coil or the copper lines. If ice is there, our frozen coil guide covers what to do while you wait.
When you book, send the brand, the model if you have it, what the thermostat is set to, and whether the outdoor unit runs. If it cools for a while and then stops, say how long. If the thermostat was replaced recently, mention that too.
Book a heat pump repair visit, see ductless mini-split repair, or contact us. Fremont had the most of these calls, then Hayward, San Ramon and Dublin. Local pages: San Ramon, Danville, Pleasanton and Walnut Creek. For the opposite season, see heat pump blowing cold air in heat mode and switching from cooling to heating in the fall.
Key takeaways
- On 6 of the 8 heat pumps and mini-splits in our cooling calls from June 1 to November 13, 2026, the refrigerant side was the problem: a low charge, a leak or an empty system.
- On the 19 central ACs with a cooling complaint, 10 needed a new capacitor, contactor or both, and 2 needed refrigerant.
- Goodman's owner checklist is short: thermostat setting, a 15-minute wait, breakers and fuses, the indoor disconnect, anything covering the outdoor unit, blocked vents, the filter and any unusual noise.
- Refrigerant, the reversing valve and anything inside the outdoor unit's electrical panel belong to a technician. The $99 diagnostic is credited toward an approved repair, and a written estimate comes before repair work.
Related questions
Why is my heat pump running but not cooling?
My heat pump heats fine but won't cool. What does that point to?
Should I keep resetting the breaker if the outdoor unit won't start?
Can I add refrigerant to my heat pump myself?
What does a heat pump cooling repair cost?
Need help with your system? Call (925) 999-4095 or book a visit. Repair diagnostics are $99, credited toward the repair. Installation assessments are free.
Further reading
Need HVAC help in the Bay Area?
We serve 65 cities. Same or next day when we can.
Bay Area · 7am–7pm · 7 days · no overtime charges